John Deere 450CLC Excavator — Check Coolant

Maintenance—Every 1000 Hours 2. Insert 4 mm hex wrench (4) into hole (5) and turn counterclockwise. 3. Slowly turn cap (1) counterclockwise. Remove cap. 4. Remove screw from top of cap. 5. Remove and discard breather element. 6. Install new breather element. 7. Install screw. 8. Install cap to case assembly (3) by aligning marks (2) and turning cap clockwise to lock position. 9. Tighten cap. 1— Cap 2— Aligning Marks 3— Case Assembly 4— Hex Wrench 5— Hole T135189 —UN—06NOV00 VD76477,0000056 -19-29JUN06-2/2 Check Coolant See Check Coolant in Maintenance—As Required. (Section 3-3.) JH91824,000050F -19-26FEB09-1/1 3-9-4 060313 PN=106