John Deere 450CLC Excavator — Drain Cooling System

Maintenance—Every 2000 Hours Drain Cooling System IMPORTANT: Avoid mixing different brands or types of coolant. Coolant manufacturers engineer their coolants to meet certain specifications and performance requirements. Mixing different coolant types can degrade coolant and machine performance. T140550B —UN—26MAR01 Drain and flush cooling system using commercial products, replace radiator cap, and refill with new coolant. 1. Check coolant hoses for cracks and leaks. Replace if necessary. 2. Check radiator and oil cooler for dirt, grease, leaks, and loose or broken mountings. Clean radiator and oil cooler fins. CAUTION: Prevent possible injury from hot spraying water.

DO NOT remove radiator filler cap unless engine is cool. Then turn cap slowly to the stop. T141316B —UN—11APR01 3. Release air to relieve pressure. Remove filler cap. Specification Cooling System—Capac- ity.......................................................................................50 L (13.2 gal) 4. From under machine, turn radiator drain valve (1) counterclockwise to open valve. Allow coolant to drain into a container. Dispose of waste coolant properly. Close drain valve. 1— Radiator Drain Valve 2— Engine Block Drain Valve 5. Turn engine block drain valve (2) counterclockwise to open valve. Drain coolant into a container. Dispose of waste properly. Close drain valve.

VD76477,000010B -19-22JUL05-1/1 3-10-2 060313 PN=108