John Deere 450CLC Excavator — Operator Station Checks—Engine On

Miscellaneous—Operational Checkout Precision Mode Circuit Check T141363 —UN—27JUN01 DISPLAY SELECT SET WORKMODE 2 T141365 —UN—20APR01 1— Precision Mode Switch 2— Precision Mode Indicator Push precision mode switch (1) to ON. YES: Go to next check. Does precision mode indicator (2) light? NO: Check fuses 2, 4, and 6 in fuse box. Go to your authorized dealer. VD76477,0000057 -19-12SEP12-7/27 Engine RPM Dial Checks min-1 Slow Idle 1 T137611 —UN—05FEB01 1— Engine RPM Dial Auto-idle/auto-acceleration switch OFF. Move engine RPM dial (1) clockwise. Does engine speed increase? Move engine RPM dial counterclockwise. YES: Go to next check. Does engine speed decrease? NO: Go to your authorized dealer.

Continued on next page VD76477,0000057 -19-12SEP12-8/27 4-3-5 060313 PN=147