John Deere 450CLC Excavator — Using Booster Batteries—24 Volt System

Operation—Operating the Machine Using Booster Batteries—24 Volt System Before boost starting, machine must be properly shut down to prevent unexpected machine movement when engine starts. CAUTION: An explosive gas is produced while batteries are in use or being charged. Keep flames or sparks away from the battery area. Make sure the batteries are charged in a well ventilated area. T137512 —UN—25JAN01 IMPORTANT: The machine electrical system is a 24-volt negative (-) ground. Connect two 12-volt booster batteries together in series as shown for 24 volts. Two Battery Application 1.

Connect one end of the positive (+) cable to the positive terminal of the machine batteries and the other end to the positive terminal of the booster batteries. 1— Machine Batteries 2— Booster Batteries 2. Connect one end of the negative (-) cable to the negative terminal of the booster batteries. Connect other end of the negative cable to the machine frame as far away from the machine batteries as possible. 4. Immediately after starting engine disconnect end of the negative (-) cable from the machine frame. Then disconnect the other end of the negative (-) cable from the negative terminal of the booster batteries. 5.

Disconnect positive (+) cable from booster batteries and machine batteries. 3. Start engine. DW90712,000016E -19-29JUN06-1/1 2-2-4 060313 PN=44