John Deere 450CLC Excavator — John Deere COOL-GARD™ II Coolant Extender

Maintenance—Machine Light Duty Diesel Engine Coolant (for diesel engines without wet sleeve cylinder liners) The engine cooling system is filled to provide year-round protection against corrosion and cylinder liner pitting, and winter freeze protection to -37°C (-34°F). If protection at lower temperatures is required, consult your John Deere dealer for recommendations. Protects the cooling system metals (cast iron, aluminum alloys, and copper alloys such as brass) from corrosion. The coolant concentrate or prediluted coolant shall be of a quality that is suitable for all-aluminum engines. The following engine coolants are preferred:

John Deere COOL-GARD™II Premix John Deere COOL-GARD II PG Premix Water Quality Water quality is important to the performance of the cooling system. Distilled, deionized, or demineralized water is recommended for mixing with ethylene glycol base engine coolant concentrate. Use John DeereCOOL-GARD™II PG Premix when a non-toxic coolant formulation is required. Coolant Drain Intervals Additional Recommended Coolants Drain and flush the cooling system and refill with fresh coolant at the indicated interval, which varies with the coolant used. The following engine coolant is also recommended: John Deere COOL-GARD II Concentrate in a 40—60% mixture of concentrate with quality water.

When John Deere COOL-GARD II is used, the drain interval is six years or 6000 hours of operation. Other Coolants When John Deere COOL-GARD II PG is used, the drain interval is five years or 5000 hours of operation. Other ethylene glycol or propylene glycol base coolants may be used if they meet one of the following specifications: ASTM D3306 prediluted (50%) coolant ASTM D3306 coolant concentrate in a 40—60% mixture of concentrate with quality water If a coolant other than COOL-GARD II or COOL-GARD II PG is used, reduce the drain interval to two years or 2000 hours of operation. IMPORTANT: Do not use cooling system sealing additives or antifreeze that contains sealing additives.

If these coolants are unavailable, use an engine coolant concentrate or prediluted coolant with a minimum of the following chemical and physical properties: Is formulated with a quality nitrite-free additive package. Do not mix ethylene glycol and propylene glycol base coolants. COOL-GARD is a trademark of Deere & Company DX,COOL18 -19-20APR11-1/1 Drain Intervals for Diesel Engine Coolant Drain and flush the cooling system and refill with fresh coolant at the indicated interval, which varies with the coolant used.

If John Deere COOL-GARD™II Premix, COOL-GARD II PG Premix, or COOL-GARD II Concentrate is used, but the coolant is not tested OR additives are not replenished by adding John Deere COOL-GARD II Coolant Extender, the drain interval is four years or 4000 hours of operation. This drain interval only applies to COOL-GARD II coolants that have been maintained within a 40—60% mixture of concentrate with quality water. John Deere COOL-GARD™II Premix, COOL-GARD II PG Premix and COOL-GARD II Concentrate are maintenance free coolants for up to six years or 6000 hours of operation, provided that the cooling system is topped off using only John Deere COOL-GARD II Premix or COOL-GARD II PG Premix.

If a coolant other than COOL-GARD II, or COOL-GARD II PG is used, reduce the drain interval to two years or 2000 hours of operation. Test the coolant condition annually with Coolant Test Strips designed for use with John Deere COOL-GARD II coolants. If the test strip chart indicates that additive is required, add John Deere COOL-GARD II Coolant Extender as directed. COOL-GARD is a trademark of Deere & Company DX,COOL11 -19-14APR11-1/1 3-1-3 060313 PN=67