John Deere 450CLC Excavator — Open Access Doors for Service

Maintenance—Periodic Maintenance Service Machine at Specified Intervals Perform service on items at multiples of the original requirement. For example, at 500 hours also service those items (if applicable) listed under 250 hours, 100 hours, 50 hours, and 10 hours or daily. Lubricate, make service checks, and make adjustments at intervals shown on the periodic maintenance chart and on the following pages. TX14740,0001C9F -19-17JUL07-1/1 Check the Hour Meter Regularly Check the hour meter (1) to determine when your machine needs periodic maintenance. Intervals on the periodic maintenance chart are for operating in normal conditions.

If you operate your machine in difficult conditions, you should service it at SHORTER INTERVALS. T140166 —UN—21MAR01 DISPLAY SELECT 1 1— Hour Meter TX14740,0001CEE -19-29JUN06-1/1 Prepare Machine for Maintenance 1. Park machine on a level surface as shown. 2. Stop engine. T6811AI —UN—18OCT88 TX14740,0001C3D -19-06MAY08-1/1 Open Engine Hood for Service CAUTION: Prevent possible injury. Unlock latch. Pull open latches to unlock hood. Raise the hood until lock stay completely engages with lock groove inside the cover. T140175 —UN—27MAR01 Raise hood using handle on hood until lock stay (1) completely engages lock groove (2) inside the cover.

1— Lock Stay 2— Lock Groove TX14740,0001CEF -19-29JUN06-1/1 3-2-1 060313 PN=74