John Deere 450CLC Excavator — Drain Hydraulic Tank Sump

Maintenance—Every 250 Hours Check Radiator Coolant Level CAUTION: Prevent possible injury from hot spraying water. DO NOT remove radiator filler cap (1) unless engine is cool. Then turn cap slowly to the stop. Release air to relieve all pressure before you remove cap. T6642EK —UN—01NOV88 1. Slowly remove cap (1). Coolant level must be at bottom of the filler neck. NOTE: If radiator coolant level is low, check for leaks on radiator cap, and hose connections between radiator and coolant recovery tank. IMPORTANT: Avoid mixing different brands or types of coolant. Coolant manufacturers engineer their coolants to meet certain specifications and performance requirements.

Mixing different coolant types can degrade coolant and machine performance. T140495 —UN—08JUN01 2. Add coolant, if necessary. 3. Install filler cap. 1— Radiator Cap VD76477,0000109 -19-22JUL05-1/1 Drain Hydraulic Tank Sump CAUTION: High pressure release of oil from pressurized system can cause serious burns or penetrating injury. The hydraulic tank is pressurized. DO NOT remove hydraulic cap. Relieve pressure by SLOWLY loosening cap. T135008 —UN—01NOV01 1. SLOWLY loosen cap (1) to relieve pressure. 1— Hydraulic Cap 2— Hydraulic Oil Tank Cover Continued on next page VD76477,0000054 -19-29JUN06-1/2 3-7-5 060313 PN=94