MAINTENANCE SECTION 5 Page 45 HYDRAULIC SYSTEM IMPORTANT: The reservoir must be refilled in this manner until the proper level is maintained after the hydraulic system is operated at least five complete cycles (boom raise and lower plus bucket close and dump operations). 5.14.3. CHANGING THE HYDRAULIC OIL RETURN FILTER (Fig. 5.37) Replace the oil filter according to the Maintenance Schedule or when the filter warning light comes on (if equipped). 1. Drain the reservoir as described in section 5.14.2. 2. Remove filter element (1) from header (4) by turning the element counterclockwise (the filter is located at the back of the reservoir). 3. Remove indicator assembly (2) from the element.
Inspect and, if necessary, replace O-ring (5). 4. Remove and inspect O-ring (3); if worn or deteriorated, replace. 5. Install O-ring (3). 6. Place indicator assembly (2) in new filter element (1). 7. Apply a light coating of clean engine oil or chassis grease to the seal surface on new filter (1). 8. Install the new filter, turning it until the O-ring just contacts filter header (4). 9. Make aligning marks on the filter and the filter header; give the filter an additional ј to Ѕ turn. IMPORTANT: Do not overtighten the filter or use any tools for installation because this can damage the O-ring or filter. In CE version it is not necessary to drain the reservoir to replace the return filter.
The oil level is below the filter header and so the oil will not flow out of the reservoir while the element is being removed. The element should be replaced when the filter warning light comes on. To replace the filter element carry out as follow: 1. Remove cover (3) from filter header (2, Fig. 5.37A). 2. Remove old element (1) and replace it with a new one. 3. Clean the dismantled parts and install cover (3). Fig. 5.37. Hydraulic Reservoir Return Filter 1. Filter Element 2. Indicator Assembly 3. O-Ring 4. Filter Header 5. O-Ring 6. Indicator DRESSTA OM515C520C99/1E