SECTION 2 SAFETY PRECAUTIONS Page 10 2.5. WHEN PARKING Avoid parking on a slope. If necessary to park on a slope, park at a right angle to the slope and block the tires. Park the machine in place free from grease and fuel to prevent tire damage. Never leave the machine with the engine running or the bucket raised. When parking a machine, shut off the engine, lower the bucket to the ground, lock the transmission shift lever in neutral (N), apply the parking brake, turn off the starting switch and the electric system master switch, and remove the keys. Park the machine in a nontraffic area.
If parking near or in traffic lanes cannot be avoided, identify the machine in accordance with traffic rules. Always lock the machine, including any anti-vandalism attachments when leaving it unattended. If the loader is equipped with a multi-purpose bucket, close the clam before dismounting. When operating in bad weather and storm lightning is nearby, dismount and seek shelter away from the machine. Lightning will be attracted to the machine and cause serious injury or death. ADDITIONAL INFORMATION 1. The vibration level measured at the operator’s seat does not exceed the admissible value of 1.25 [m/s 2 ] according to PN-91/N-01352 standard. 2.
The noise level measured at the operator’s seat during intensive operation does not exceed the admissible value of 85 [dB] (A) according to PN-86/M-47015. 3. Sound level L A produced by a machine does not exceed a value of 85 [dB] (A) according to PN-86/M-47016. 4. A loader can be operated in temperature ranging from -34 [ o C] to +49 [ o C]. A wheel loader in standard configuration is not adapted to operation in terrain where a mixture of gasses, vapors, aerosols or dust with air creates explosion hazard zones. 5. A wheel loader in CE configuration was given TЬV Hannover Laboratory DE 10-893 641 16 Noise Level Certificate on 17 May 1999.
The level of noise produced by a brand new machine reached 104 [dB] (A) when measured according to ISO-6395 standard (admissible value according to EEC/662/86 directive is 107 [dB] (A)). OM515C520C99/1E DRESSTA