Alternator Touch one probe of the ohmmeter to the bare metal surface of stator and the other probe to a bare stator lead wire. Repeat for each wire. Replace stator if test indicates continuity. Test the diodes by touching probes to output post and the three outer terminals. Switch the probes and check each terminal again. There should be continuity in only one direction between each terminal and the output post. 1 M36741 Rectifier: M36743 Output Post NOTE: The three inner terminals are connected by a printed circuit in the rectifier. Test the diodes by touching probes to ground post and the three outer terminals. Test the three inner terminals using an ohmmeter.
Move probes so all terminals are cross checked. Replace the rectifier if test shows no continuity. Switch the probes and check each terminal again. There should be continuity in only one direction between each terminal and the ground post. A shorted diode would have continuity in both directions. An open diode would have no continuity in either direction. Replace the rectifier assembly if any of the six diodes are defective. Inner Terminals M36742 NOTE: Each of the three outer terminals on the rectifier is connected to two diodes permitting current flow in only one direction. Ground Post M36744 4/7/95 1-127 AllTractorManuals.com