Komatsu — EVERY 2000 HOURS SERVICE

EVERY 2000 HOURS SERVICE 5. Remove spring (6) and bypass valve (71, then remove element 7. Pour in the specified quantity of engine oil from filler (F). Bleed the air from the hydraulic circuit as follows. 1. Run the engine at low idling, loosen air bleed plug (I) at the top of the oil filter case, and leave until the oil starts to overflow. (8). * Check that there is no foreign matter inside the tank before cleaning it. 6. Install a new element, then install bypass valve (71, spring (61, and cover (4). Ir If the O-ring of the cover is dam- aged or deteriorated, replace it with a new part. * When installing the cover bolts, push down the cover and tighten the bolts evenly. * Refill capacity:

2 17 Q 8. Start the engine, raise and lower the work equipment, and operate the steering to circulate the oil. Then lower the blade horizontaly to the ground and stop the engine. 9. Check the oil level and ensure that is correct. (Refer to EVERY 100 HOURS SERVICE.) Sr Check that there is no oil leaking from the filter cover mount. Sr The type of lubricant used de- pends on the ambient tempera- ture. Select according to the 2. Tighten air bleed plug (I 1. Ir Tightening torque: 1.15 kO.15 kgm 3. Operate each cylinder to the end of its stroke, depress the acceler- ator pedal fully, and keep in this position for approx. 1 minute. Carry out this operation 3 - 5 times for each cylinder.

table “FUEL, COOLANT AND LUBRICANTS”. w-03740 - 109-