Komatsu — WHEN REQUIRED

WHEN REQUIRED WHEN REQUIRED a. CLEAN INSIDE OF COOLING SYSTEM Clean the inside of the cooling system, change the coolant, and re- place the corrosion resistor, accord- ing to the table. * * Be sure to replace the corrosion resistor cartridge. * Use city water for the cooling wa- ter. Add antifreeze in the cooling water When deciding the ratio of anti- freeze to water, check the lowest temperature in the past, and de- cide from the mixing rate table given below. It is actually better to estimate a temperature about 10°C lower when deciding the mixing rate.

Mixing rate of water and antifreeze Stop the machine on level ground If river water, well water or other when cleaning or changing the such water supply must be used, coolant. contact your Komatsu distributor. * Use a permanenttype of antifreeze. If, for some reason, it is impossible A Antifreeze is flammable, so keep it to use permanent type antifreeze, away from any flame. use an antifreeze containing ethyl- ene glycol. Min.

atmospheric temperature f”C ) Amount of antifreeze (Q) Type of antifreeze solution Cleaning inside of coolina svstem and changing coolant Replacing corrosion resistor Permanent type antifreeze (All season type) Every year (autumn) or every 2000 hours whichever comes first Amount of water (Q) Non permanent type antifreeze containing ethylene glycol (Winter, one season type) ;E,e:k;;7onths (spring, Every 1000 hours and when cleaning the inside of the cooling system and when changing coolant Sr We recommend use of an antifreeze density gauge to control the mix- ing proportions..

(Drain antifreeze in spring, add antifreeze in autumn) When not using antifreeze Every 6 months or every 1000 hours whichever comes first - 116-