mercedes-benz — Mercedes-Benz Automated-Manual Transmissions Troubleshooting Guide

Cab Heater and Air Conditioner, Valeo 83.00 Specifications Day Cab with Valeo HD-1 Condenser Ambient Air Temp: °F (°C) Humidity (approximate) Dash Outlet Temperature (approximate) Service Port Pressures A/C Compressor Status A/C Compressor Status Comments High: psi (kPa) Low:

psi (kPa) Low 25% 50–56°F (10– 13°C) 80–100 (552–689) 12–53 (83–365) Cycling On 4 sec; Off 11 sec Med 50% 52–56°F (11– 13°C) 80–95 (552– 655) 13–52 (90–359) Cycling On 5 sec; Off 10 sec 70 (21) High 70% 53–58°F (12– 14°C) 85–105 (586–724) 14–55 (97–379) Cycling On 6 sec; Off 6 sec Low 25% 52–58°F (11– 14°C) 120–125 (827–862) 16–58 (110–400) Cycling On 6 sec; Off 9 sec 80 (27) Med 50% 54–60°F (12– 16°C) 120–125 (827–862) 18–60 (124–414) Cycling On 12 sec; Off 8 sec High 70% 53–61°F (12– 16°C) 120–135 (827–931) 19–59 (131–407) Cycling On 26 sec; Off 4 sec 90 (32) Low 25% 51–57°F (12– 14°C) 125–150 (862–1034) 18–59 (124–407) Cycling On 7 sec; Off 5 sec Med 50% 51°F (12°C) 155 (1069) 21 (145) On On steady Very Low 10% 52–63°F (11– 17°C) 140–170 (965–1172) 18–60 (124–414) Cycling On 19 sec; Off 4 sec, then On 6 sec; Off 9 sec 100 (38) Low 25% 50°F (10°C) 175 (1207) 20 (138) On On steady Test conditions:

Med 40% 54°F (12°C) 180 (1241) 23 (159) On On steady engine at 1500 rpm engine fan locked on normal A/C mode, outside air blower speed on high, about 13.5 vdc cab doors open hood open parked out of direct sunlight no wind speed or less than 5 mph (8 km/h) stabilize at each point Table 9, Day Cab with Valeo HD-1 Condenser Business Class M2 Workshop Manual, Supplement 15, March 2009 400/9