mercedes-benz — Mercedes-Benz Automated-Manual Transmissions Troubleshooting Guide

Meritor WABCO Hydraulic Antilock Braking System (ABS) 42.26 Troubleshooting J1587 Fault 136-048 Left Front Outlet Solenoid Valve MID SID FMI Problem Test Test Result Action 1. Measure the resistance across Pins 10 and 2 of the gray X1 ECU connector (Circuits 378LFO and GRDE). Resistance reading 3.5±0.5 ohms Check for intermittent wiring connections. If the wiring is OK, suspect the ECU is at fault. Resistance reading not 3.5±0.5 ohms Go to Test 2. 2. Check the ground circuit by measuring the resistance between Pin 2 of the gray X1 ECU connector and a good chassis ground. Resistance reading close to zero Go to Test 3.

Resistance reading not close to zero Shorted to power (outlet valve) Check and repair the ground circuit. Open circuit (outlet valve) 3. With the modulator valve connector removed, measure the resistance between Pin 8 on the modulator connector and a good chassis ground. Resistance reading close to zero Go to Test 4. 03 Shorted to ground (outlet valve) 136 048 05 NOTE: Check for an open circuit in the wiring between the ECU and the modulator valve. Check the ground circuit to the modulator valve. Resistance reading not close to zero Check the modulator ground circuit, repair as necessary. 06 4.

Measure the resistance in Circuit 378LFO between modulator connector Pin 13 and connector Pin 10 on the gray X1 ECU connector. Resistance reading close to zero Go to Test 5. Resistance reading not close to zero Repair Circuit 378LFO. Repeat Tests 1 through 5. The problem may be intermittent. If the wiring is OK, suspect the ECU is at fault. 5. With the modulator valve connector removed, measure the resistance across Pins 13 and 8 on the modulator connector. Resistance reading 3.5±0.5 ohms Resistance reading not 3.5±0.5 ohms Replace the modulator valve. Table 16, J1587 Fault 136-048 Left Front Outlet Solenoid Valve Business Class M2 Workshop Manual, Supplement 4, March 2003 300/22