. MAINTENANCE SERVICE PROCEDURE EVERY 4000 HOURS SERVICE REPLACE ACCUMULATOR (FOR CONTROL CIRCUIT) WARNING accumulator. 4 - 81 Maintenance for every 50, 250, 500, 1000 an d 2000 hours s ervice should be carried o Replac e the accumula tor every 2 years or ev ery 4000 hours , whichever comes soone The acc umulator is char ged with high-pressure nit rogen gas, so mis taken operation may cause an explosion, which will lead to serious injury or damage . When handling the accu mulator, always d o as f ollows. The pressure in the h ydraulic circuit cannot be completely removed.
W hen removing the hyd raulic equipment, do not stand in th e direction that th e oil spurts out when carr ying out the operation. In addition, loosen the bolts slowly when carrying out the o peration. he accumulator. ame or dispose of it in fire. it or weld it. subject it to any impact. Do n ot disassemble t Do n ot bring it near fl ame or dispose of it in fire. Do n ot make holes in Do n ot hit it, roll it, or Whe n disposing of th e accumulator, the gas m ust be released. Pleas e contact your Komats u distributor to have this work carri ed out.
If operations are cont has dropped, it beco inued when the functio mes impossible to rel n of accumulator (1) ease the remaining pressu machin If this CHECK WATER PU MP Check that there is no play in the pulley, leaka ge of oil or wate r, or c logging of the drain h ole. If any problem is found, please contact your K omatsu distributor for re pairs or replacemen t. CHECK STARTING Contac t your Komatsu distributor to have the starting motor checked. If t he e ngine is started frequently, have this in spection carrie d out