Komatsu — OTHER TROUBLE

. OPERATION TROUBLES AND ACTIONS Machine Monitoring System (*): For details of handling the emergency pump drive switch and emergency boom swing operation/brake cancel switch, see "SWITCHES (PAGE 3-14)". 3 - 139 Electronic Control System If an error code appears on machine monitor display (1) (normally displays TIME), follow the countermeasure table for the self-diagnosis as shown below. Monitor display Error mode Countermeasure E02 Pump control system error If emergency pump drive switch is set to the ON position, operation can be carried out. However, immediately have the system inspected by your Komatsu distributor.

(*) E03 Swing brake system error Turn the emergency boom swing operation/brake cancel switch ON to release the brake. Depending on the cause of the failure, it may be possible to release the brake. In ant case, have the system inspected immediately by your Komatsu distributor. (*) E41 Boom swing system error If emergency boom swing operation/brake cancel switch is set to the ON position, operation can be carried out. However, immediately have the system inspected by your Komatsu distributor. (*) E05 Governor system error Fuel adjusting dial is inoperative. Either or both of acceleration or deceleration cannot be operated, depending on a failure mode.

In any case, call for inspection service immediately. Have the machine inspected immediately by your Komatsu distributor. Have the machine inspected immediately by your Komatsu distributor.