daewoo Solar 140LC-V — Hydraulic Breaker Operation

HYDRAULIC HOSES AND TUBING FOR BREAKER 1. When installing hydraulic breaker, assemble according to drawings provided with kit. 2. If breaker is taken off excavator, be sure to plug and cap all hoses and tubing to prevent contamination from entering hydraulic system. 3. Plug and cap all connectors and fittings on breaker to prevent contamination. 4. Check all hydraulic connections for signs of leaks or loose components before starting operation. HYDRAULIC BREAKER OPERATION NOTE: Hydraulic pressure and flow settings may need to be changed. Refer to the Maintenance Section of this manual for further information. 1. Make sure to read and understand the breaker user's manual. 2.

Inspect all mechanical and hydraulic connections. 3. Do not use the breaker as a hammer. See Figure 71. Do not drop breaker from extreme heights. The breaker is relatively heavy and drops fast. Do not drop breaker from extreme heights or damage to upper structure may result. HAOB930L Figure 71 4. Do not operate the breaker with the boom or arm cylinders fully extended (bottomed out). See Figure 72. Leave over 100 mm (4 in) of clearance between rod end of cylinder and cylinder head. This will help prevent damage to cylinders during breaker operation. HAOB940L Figure 72 022-00058E Operation and Maintenance Manual Operation 3-33