daewoo Solar 140LC-V — Check Air Conditioner Refrigerant

4-42 Inspection, Maintenance and Adjustment 022-00058E Operation and Maintenance Manual CHECK AIR CONDITIONER REFRIGERANT WARNING! Mixing of tobacco smoke and freon is deadly. Do not smoke while servicing or recharging air conditioning system. 1. Run engine about 1800 rpm. Operate for a minimum of ten minutes to stabilize the system. 2. Press the "HI" fan speed switch to set maximum air flow. 3. Put the temperature control switch in maximum cool position. 4. Press the "Internal Air Circulation" switch. 5. Compare the flow of bubbles in the sight glass of receiver dryer with the drawings in the following table. Figure 72 CAUTION!

Overfilling refrigerant may cause dangerous high-pressure and poor cooling action; and low refrigerant level may cause compressor damage. Always maintain refrigerant at normal level. Amount of Refrigerant Appearance of the Sight Glass Solutions Normal Almost clear. Any bubbles disappear. High No bubble is seen. Charge or with draw the system with the correct amount of HFC-134a refrigerant. Low A flow of bubbles is visible.