. MAINTENANCE SERVICE PROCEDURE CLEAN INSIDE OF COOLING SYSTEM WARNING Komatsu genuine SUPERCOOLANT (AF-NAC) has the important function of preventing corrosion as well as preventing freezing. Even in the areas where freezing is not an issue, the use of coolant is essential. Komatsu machines are supplied with SUPERCOOLANT (AF-NAC). SUPERCOOLANT (AF-NAC) has excellent anticorrosion, antifreeze and cooling properties and can be used continuously for 2 years or 4000 hours. As a basic rule, we do not recommend the use of any coolant other than SUPERCOOLANT (AF-NAC). If you use another coolant, it may cause serious problems, such as corrosion of the engine and aluminum parts of the cooling system.

To maintain the anticorrosion properties of coolant, always keep the density of coolant between 30% and 64%. When selecting coolant, investigate the lowest temperature in the past and decide the density for the coolant from the coolant density table below. When actually deciding the density for the coolant, set it approximately 10 ° C (50 ° F) below lowest temperature. The density must be over 30% at least. If the density of obtained coolant is higher than the necessary density for lowest temperature, dilute it with adequate distilled water, and then fill it into the tank. If there is any unclear point, contact your Komatsu distributor.

Coolant density table 4 - 28 Immedi ately after the engine is stoppe d, the engine c oolan t is h ot and the pressure inside the sub-tank is high. Removing the cap an d draining the water under this conditio n coul d cause bu rns. A llow the engine to cool down, the n turn the cap slowly to relea se the pressu re. Start th e engine and f lush the system. When standing up or leavi ng the operator's seat, set the shift lever t o N (neutral) position and set the parking b rake switch to P ARKING positio n.

For det ails of startin g the engine, see "OPERATIONS , CHECKS BEFORE STARTING (PAGE 3-84)" and "STARTING ENGINE (PAGE 3-85)" in the O PERATION secti on of the Operation a nd M aintenanc e Manual When t he undercove r is removed, the re is danger of t ouching th e fan. Never g o to the front of the machine w hen the engine is running Stop the machine on level ground w hen cleaning or changi ng the coolant. Clean the inside of th e cooling syste m, change th e coolant accordin g to the t able below.

Interv Coolant al for cleaning inside of cooling system and changing antifreeze coolant Komatsu genuine SUPERCOOLANT (AF-NAC) Every 2 years or every 4000 hours whichever comes sooner Minimum Temp °C Above -10 -15 -20 -25 -30 -35 -40 -45 -50 °F Above 14 5 -4 -13 -22 -31 -40 -49 -58 Density (%) 30 36 41 46 50 54 58 61 64