volvo — PV776-QRG07-MP8.pdf

146 BASIC SERVICE W2033382 6. Install and tighten the V-band clamp that joins the outlet module to the exhaust pipe. 7. Secure the DPF bracket to the chassis frame bracket and tighten all fasteners to specification. W2033381 8. Remove the transmission jack from under the assembly. 9. Install the pressure differential sensor tube that connects to the outlet module and tighten fitting to specification. Note: A high-temperature anti-seizing compound should always be applied to the threads of the sensors, plugs and fittings in the exhaust system to avoid component seizure or corrosion. 10. Install the lines and sensors connecting the various modules to each other.

Refer to torque specifications for the V-band clamp screws, lines and sensors in the SPECIFICATIONS section of this manual 11. Install the fairing (if equipped), braces and steps that were removed to permit access. 12. Using Premium Tech Tool (PTT), ensure all soot trigger levels are reset back to zero.