OM4026.2 4/00 Rotary Pump Maintenance - Section 4 Automatic Lubrication System Page 4-17 Pressure Failure Detection Circuits: 3. If a problem occurs and the system is not able to attain 2000 psi (13.8 MPa), the delay timer (11) will energize relay RB7K4 (12) after 60 seconds, turning on the “Low Lube System Pressure” warning lamp on the overhead display. After RB7K4 relay energizes, it will energize relay RB7K3 (10). 1. When the lubrication cycle is initiated, 24VDC flows through relay RB7K1 (7, Figure 4-5) N.C. contacts to a 1 minute delay timer (11). 2.
If the system is operating normally, grease pres- sure at the rear axle injector bank will rise to pressure switch (6) setting of 2000 psi (13.8 MPa) and energize relay RB7K1 (7), removing 24VDC from the delay timer. 4. Once RB7K3 is energized, it will latch and remain energized as long as the keyswitch is on. In addition, RB7K4 will also remain energized and the Low Lube Pressure Warning lamp will remain on to notify the operator a problem exists and the system requires service. FIGURE 4-5. ELECTRICAL SCHEMATIC 1. Lubrication Cycle Timer 2. Circuit Breaker CB7 (In Electrical Interface Cabinet) 3. Pressure Switch; N.O., 2500 psi (17 237 kPa) 4. Relay K5 (On Relay Board RB7) 5.
Grease Pump Motor Solenoid Valve 6. Pressure Switch; N.O. 2000 psi (13 790 kPa) 7. Relay K1 (On Relay Board RB7) 8. Lube System Manual Test Switch 9. Circuit Breaker CB9 (In Electrical Interface Cabinet) 10. Relay K3 (On Relay Board RB7) 11. Circuit Time Delay Module 12. Relay K4 (On Relay Board RB7) 13. Low Grease Pressure Warning Lamp (On Overhead Display Panel) 14. Warning & Caution Lamp Test Switch (On Overhead Display Panel)