Specifications - 82 SK800 Operator’s Manual SK800 p Auxiliary: double gear pump Ground drive: dual hydrostat Battery SAE reserve capacity 110min, SAE cold crank @ 0°F (-18°C) 800amp, 12V electrical system Vibration Levels Average vibration transmitted to the operator’s hand during normal operation with a loader bucket is 4.31m/sec 2 . Average vibration transmitted to the whole body during normal operation with a loader bucket is 1.07m/sec 2 . Actual vibration will depend on the attachment being used. Noise Level This machine can generate sound levels exceeding 80dBA. Always wear appropriate hearing protection when operating machine.
Find sound power and pressure information at www.ditchwitch.com, or contact customersupport@ditchwitch.com. Specifications are called out according to SAE recommended practices. Specifications are general and subject to change without notice. If exact measurements are required, equipment should be weighed and measured. Due to selected options, delivered equipment may not match that shown.
Power Plant US Metric 3000rpm Hydraulic System US Metric Flow rate (pump 1) 6.5gpm 24L/min Flow rate (pump 2) 5.5gpm 21L/min Pressure 3000psi 207bar Flow rate 12.7gpm 48.1L/min Pressure 3625psi 250bar Fluid Capacities US Metric Engine oil, with filter 5.0qt 4.7L Fuel tank 10.5gal 40L Hydraulic reservoir 9.2gal 35L