. OPERATION COLD WEATHER OPERATION BATTERY WARNING When adding distilled water in cold weather, add it before starting operations in the morning to prevent the electrolyte from freezing. CAUTIONS AFTER COMPLETION OF WORK To prevent mud, water, or the undercarriage from freezing and making it impossible for the machine to move on the following morning, observe the following precautions. Mud and water on the machine body should be completely removed. This is to prevent damage to the seal caused by mud or dirt getting inside the seal with drops of water. Park the machine on hard, dry ground. If this is impossible, park the machine on wooden boards.
The boards help protect the tracks from being frozen in soil and the machine can start next morning. Open the drain valve and drain any water collected in the fuel system to prevent it from freezing. As the battery capacity drastically drops in low temperatures, cover or remove the battery from the machine, store the battery in a warm place, and install it the next morning. AFTER COLD WEATHER When the season changes and the weather becomes warmer, do as follows. Replace the fuel and oil for all parts with oil of the viscosity specified. For details, see "RECOMMENDED FUEL, COOLANT, AND LUBRICANT (PAGE 4-10)". 3 - 175 The battery generates flamma ble gas.
D o not bring fire o r sparks ne ar the ba ttery. Battery electrolyte is dangero us. If it get s in yo ur eyes o r on your sk in, wash it off with a large amount of water and consult a doctor. electrolyte dissolves paint. If it gets on the bodywork, wash it off immediately with water. Battery electrolyte dissolves p aint. If it gets o n the body work, wash it off im mediately with water. If the battery electroly te is froz en, do no t charg e the batt ery or start the engin e with a different powe r source. There is danger that the battery may e xplode. not let it flow into drainage ditches or spray it on to the ground surface. Battery electrolyte is t oxic.
Do not let it flow in to drainag e ditches o r spray it on to the ground surface. When the ambient temperatu re drops, the ca pacity of the batter y will als o drop. If the battery charge ratio is low, the battery electrolyte ma y freez e. Mainta in the battery c harge as close a s possible 100%. Insulate cold temperature t o ensure the ma chine ca n be started e asily the n ext morning. Measure the specific gravity and calculate t he rate o f charge fr om the following conversion table. it against Electrolyte Temperature Charging Rate (%) 20°C (68°F) 0°C (32°F) -10°C (14°F) -20°C (-4°F) 100 1.28 1.29 1.30 1.31 90 1.26 1.27 1.28 1.29 80 1.24 1.25 1.26 1.27 75 1.23 1.24 1.25 1.26