Caterpillar — Maintenance Interval Schedule

91 Maintenance Section Engine Crankcase Breather - Clean Observe the service indicator. The air cleaner element should be cleaned or the air cleaner element should be replaced when one of the following conditions occur: The yellow diaphragm enters the red zone. The red piston locks in the visible position. Test the Service Indicator Service indicators are important instruments. Check for ease of resetting. The service indicator should reset in less than three pushes. Check the movement of the yellow core when the engine is accelerated to the engine rated speed. The yellow core should latch approximately at the greatest vacuum that is attained.

If the service indicator does not reset easily, or if the yellow core does not latch at the greatest vacuum, the service indicator should be replaced. If the new service indicator will not reset, the hole for the service indicator may be plugged. g00768439 Illustration 43 (1) Breather assembly (2) Bolt (3) Hose clamp (4) Hose 1. Loosen hose clamp (3) and remove hose (4) from breather assembly (1). The service indicator may need to be replaced frequently in environments that are severely dusty, if necessary. Replace the service indicator annually regardless of the operating conditions.

Replace the service indicator when the engine is overhauled, and whenever major engine components are replaced. 2. Remove bolt (2) and the washer. Remove the breather assembly (1) and the seal. 3. Wash the breather element in solvent that is clean and nonflammable. Allow the breather element to dry before installation. Note: When a new service indicator is installed, excessive force may crack the top of the service indicator. Tighten the service indicator to a torque of 2 N·m (18 lb in). 4. Install a breather element that is clean and dry. Install breather assembly (1) and the seal. 5. Install bolt (2) and the washer. Refer to the Operation and Maintenance Manual for the proper torque.

i01473536 Engine Crankcase Breather - Clean 6. Install hose (4) on breather assembly (1). Tighten hose clamp (3). Refer to the Operation and Maintenance Manual, “Torque Specifications” for the proper torques. SMCS Code: 1317-070 NOTICE Perform this maintenance with the engine stopped. i00687861 Engine Mounts - Inspect NOTICE If the crankcase breather is not maintained on a regular basis, it can become plugged. A plugged breather will cause excessive crankcase pressure that may cause crankshaft seal leakage. SMCS Code: 1152-040 Inspect the engine mounts for deterioration and for proper bolt torque. Engine vibration can be caused by the following conditions: Improper mounting of the engine