Komatsu — TROUBLESHOOTING

.

ATTACHMENTS, OPTIONS HANDLING HYDRAULIC RIPPER TROUBLESHOOTING OTHER TROUBLE Slow ripper raising and function, lack of ripping force Problem Main causes Remedy Improper hydraulic oil Add oil to specified level, see EVERY 250 HOURS SERVICE ( Check, repair) ( Check, repair) Defective pump Defective adjustment of relief valve Defective control valve, safety valve Defective valve spool Defective piston ring, packing, valve Clogging inside piping ( Check, repair) ( Check, repair) ( Check, repair) Cylinder lacks holding power Leakage of oil from piping, hose Defective piston ring, packing Defective piston valve Defective valve spool Defective safety valve, suction valve Tighten ( Replace) ( Check, repair) ( Check, repair) ( Check, repair) Oil pressure does not rise Clogging inside piping Defective adjustment of relief valve ( Repair) ( Check, adjust) 6 - 7 ( ) :

Always contact your Komatsu distributor when dealing with these items. In cases of problem or causes which are not listed below, contact your Komatsu distributor for repairs.