Aegis LH630-775 — Section 10 - Inspection and Reconditioning

Section 10 Inspection and Reconditioning Hard starting, or loss of power accompanied by high fuel consumption may be symptoms of faulty valves. Although these symptoms could also be attributed to worn rings, remove and check the valves first. After removal, clean the valve heads, faces, and stems with a power wire brush. Then, carefully inspect each valve for defects such as warped head, excessive corrosion, or worn stem end. Replace valves found to be in bad condition. A normal valve and valves in bad condition are shown in the accompanying illustrations. Bad Condition: The valve depicted here should be replaced. Note the warped head; margin damaged and too narrow.

These conditions could be attributed to excessive hours or a combination of poor operating conditions. Normal: Even after long hours of operation a valve can be reconditioned and reused if the face and margin are in good shape. If a valve is worn to where the margin is less than 1/32" do not reuse it. The valve shown was in operation for almost 1000 hours under controlled test conditions. Gum: Gum deposits usually result from using stale gasoline. Gum is a prevalent cause of valve sticking. The cure is to ream the valve guides and clean or replace the valves, depending on their condition. Leakage:

A poor grind on face or seat of valve will allow leakage resulting in a burned valve on one side only. 10.6