. OPERATION TROUBLES AND ACTIONS Machine Monitoring System (*): For details of handling the emergency pump drive switch, see "Emergency Pump Drive Switch (PAGE 3-38)". 3 - 165 Electronic Control System If an erro r code is displayed on the machine monitor display, follow the self-diagnostic remedy table below. Monitor display Failure mode Remedy E03 Swing brake system error Carry out inspection immediately. E07 Error in pump controlling system (Emergency safeguard system in action) An abnormality has occurred in the electronic pump control system, and the emergency safeguard system is in action. Part of the machine's functions is lost.
The ordinary work is still possible with the machine, but ask your distributor for an inspection. E10 Abnormality in electronic governor system (engine stopped) Carry out inspection immediately. E11 E14 Abnormality in electronic governor system (abnormality in engine protection output) Abnormality in throttle (abnormality in fuel control dial) It is possible to carry out normal working operations, but have inspection carried out immediately. Move machine to a safe posture, and carry out inspection immediately. E15 Abnormality in electronic governor system It is possible to carry out normal driving operations, but have inspection carried out immediately.
E0E Abnormality in network If the engine can be operated, set the machine to a safe posture, then have inspection carried out immediately. If the engine is operated and stalls, turn the emergency pump drive switch is up set the machine to a safe posture, then have inspection carried out immediately. Even if the engine is stopped, have inspection carried out immediately. If no error code is displayed but work equipment or swing cannot be operated Carry out inspection immediately.