S eries 300 Power Transfer Switches Maximum Reliability & Excellent Value With a S eries 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually every major technological advance in the Transfer Switch industry. The ASCO S eries 300 was designed for one purpose–to automatically transfer critical loads in the event of a power outage. Each and every standard component was designed by ASCO engineers for this purpose. The rugged construction and proven performance of the ASCO S eries 300 assure the user of many years of complete reliability.
The S eries 300 is even designed to handle the extraordinary demands placed on the switch when starting or restarting stalled motors and switching high inrush loads. ASCO’s S eries 300 modular, compact design makes it easy to install, inspect and maintain. All parts are accessible from the front so switch contacts can be easily inspected. Features The S eries 300 is listed to UL 1008 standard for Transfer Switch Equipment and CSA standard C22.2 for automatic transfer switches. Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code (NEC) Articles 700, 701 and 702. 30 through 3000 amps in a compact design. Fig. 1:
ASCO Power Transfer Switch rated 200 amperes shown in Type 3R enclosure There’s no danger of the S eries 300 ATS transferring loads to a dead source because the unique ASCO single-solenoid operator derives power to operate from the source to which the load is being transferred. Easy-to-read flush-mounted control and display panel provides LED indicators for switch position and source availability. It also includes test and time-delay bypass switches as standard features. Available to 600 VAC, single or three phase. True double-throw operation:
The single solenoid design is inherently inter-locked and prevents contacts from stopping between sources or from being in contact with both sources at the same time. UL Listed Withstand & Close-On Ratings Standard engine exerciser for weekly automatic testing of engine generator set with or without load. Adjustable time-delay feature prevents switch from being activated due to momentary utility power outages and generator dips. Supplied with solid neutral termination. Optional switched neutral pole available. Accessory kits available. Available for immediate delivery. Now available for service entrance applications. Contact Asco for assistance. Notes: 1.
Current – limiting fuse should be Class J type through 400 amps: use Class L type above 400 - amp fuse rating 2. Refer to publication 1128 for specific manufacturer’s breakers 4 66 Switch Ratings Amps Available Symmetrical Amperes RMS When Used With Current Limiting Fuses Maximum Voltage When Used With Specific Circuit Breakers 30 100,000 480v/60Hz 10,000 70 - 200 200,000 480v/60Hz 22,000 230 100,000 480v/60Hz 22,000 260, 400 200,000 480v/60Hz 42,000 6 00 200,000 600v/60Hz 42,000 6 00 200,000 480v/60Hz 50,000 600 200,000 240v/60Hz 65,000 800,1000,1200 200,000 600v/60Hz 65,000 1600, 2000 200,000 600v/60Hz 85,000 2600, 3000 200,000 600v/60Hz 100,000