Service as Required Replacing Single Stage Air Cleaner IMPORTANT: ALWAYS REPLACE air cleaner when air restriction indicator shows a vacuum of 625 mm (25 in.) H 2 O, is torn, or visibly dirty. RG11319A –UN–06SEP00 NOTE: This procedure applies to John Deere single stage air cleaner kits. Refer to manufacturers’ instructions for servicing air cleaners not supplied by John Deere. 1. If equipped, loosen body clamp. Single Stage Air Filter 2. Loosen clamp around outlet neck (A). 3. Remove air cleaner. 4. Install new filter so that overlap (B) of air cleaner outlet neck and engine intake pipe is to specification below.
RG11320 –UN–07SEP00 Specification Air Cleaner Neck to Engine Intake—Overlap 38 mm (1.5 in) .................................................................. 5. Tighten neck clamp (A) to specification below. Specification Air Cleaner Neck Clamp—Torque 6.8 (60 lb-in.) ................................. Installation of Single Stage Air Cleaner A—Outlet Neck Clamp B—Filter to Engine Overlap IMPORTANT: Do NOT overtighten body clamp. Overtightening may cause crushing of air cleaner body. Tighten body clamp only until snug. 6. If equipped, tighten body clamp until snug. IMPORTANT:
Whenever the air cleaner has been serviced or removed, ALWAYS fully depress the air restriction indicator reset button (if equipped) to assure accurate readings. 7. If equipped, fully depress air restriction indicator reset button and release to reset indicator. RG,RG34710,5594 –19–20MAY96–1/1 40-5 021604 PN=178