LIFTING CAPACITIES 5.2 LIFTING CAPACITIES 5.2.1 LIFTING CAPACITIES PC30MR-2 (WITH CANOPY) According to the standard EN474-5 (§ 4.1.7.5), this machine if not equipped with suitable devices is not allowed to lift more than 1000 kg. Do not attempt to lift loads unless the machine is standing on firm, level ground. NOTE Loads do not exceed 87% of hydraulic capacity or 78% of tipping capacity. * Load limited by hydraulic capacity rather than tipping STANDARD ARM + STANDARD WEIGHT + BLADE DOWN Unit: kg 206 DANGER A B 2 m 3 m 4 m Max.
4.0 m *875 550 3.0 m *785 490 *805 320 2.0 m *1005 470 *825 285 *805 255 1.0 m *1325 435 *1000 335 *830 235 0 m *2680 795 *1450 415 *940 270 *855 250 – 1.0 m *2155 785 *1270 420 *870 310 – 2.0 m *735 570