Kubota — 8. Adjusting air conditioner belt tension

PERIODIC SERVICE EVERY 100 HOURS 7.2 Charging the battery WARNING To avoid personal injury or death: When the battery is being activated, hydrogen and oxygen gases in the battery are extremely explosive. Keep open sparks and flames away from the battery at all times, especially when charging the battery. When charging the battery, ensure the vent caps are securely in place (if equipped). When disconnecting the cable from the battery, start with the negative terminal first. When connecting the cable to the battery, start with the positive terminal first. Never check battery charge by placing a metal object across the posts. Use a voltmeter or hydrometer. 7.3 Directions for battery storage 1.

When storing the tractor for long periods of time, remove the battery from the tractor, adjust the electrolyte to the proper level and store in a dry place out of direct sunlight. 2. The battery self-discharges while it is stored. Recharge it once every 3 months in hot seasons and once every 6 months in cold seasons. 8. Adjusting air conditioner belt tension WARNING To avoid personal injury or death: Be sure to stop the engine before checking the belt tension. 1. Stop the engine and remove the key. 2. Apply moderate thumb pressure to belt between pulleys. 3.

If tension is incorrect, loosen the tension pulley mounting nut and turn the adjusting bolt to adjust the belt tension within acceptable limits. 4. Replace air conditioner belt if it is damaged. (1) Battery 1. To slow charge the battery, connect the battery positive terminal to the charger positive terminal and the negative to the negative, then recharge in the standard fashion. 2. A boost charge is only for emergencies. It will partially charge the battery at a high rate and in a short time. When using a boost-charged battery, it is necessary to recharge the battery as early as possible. Failure to do this will shorten the battery's service life. 3.

The battery is charged when the indicator display turns from black to green. 4. When exchanging an old battery for a new one, use a battery of equivalent specification to those shown in the following table. (1) Adjusting bolt (2) Tension pulley mounting nut (A) Check the belt tension (B) To tighten Table 1 122 M5091,M5111 Reserve capacity (min) Cold cranking amps Normal charging rate (A) 160 900 11 Proper air condi- tioner belt tension A deflection of between 10 to 12 mm when the belt is pressed (98 N / 10 kgf) in the middle of the span. Battery type Volts (V) Capacity at 5H.R (A.H) GP31 (105E41R) 12 80