Kubota — 2. Antifreeze

PERIODIC SERVICE EVERY 2000 HOURS OR 2 YEARS 6. After flushing, fill with clean soft water and anti- freeze until the coolant level is just below the radiator cap. Install the radiator cap securely. 7. Fill with coolant up to the [FULL] mark of the recovery tank. 8. Start up and operate the engine for a few minutes. 9. Stop the engine, remove the key and let it cool down. 10. Check the coolant level of the recovery tank and add coolant if necessary. 11. Properly dispose of the used coolant. (1) Radiator cap (2) Recovery tank IMPORTANT : Do not start the engine without any coolant. Use clean, fresh soft water and antifreeze to fill the radiator and recovery tank.

When mixing the antifreeze with water, the antifreeze mixing ratio is 50%. Securely tighten the radiator cap. If the cap is loose or improperly fitted, water may leak out and the engine could overheat. NOTE : On CAB type machines, coolant circulates through the heater. This means that approximately one more liter of coolant is required. In changing coolant, pour coolant up to the filler port of the recovery tank. Turn the heater (shift the temperature control dial toward ), and run the engine for a while in order to warm coolant. Then stop the engine. When the coolant has cooled down, some of the coolant in the recovery tank is drawn into the pipes.

Now the recovery tank is appropriately filled with coolant. (1) Drain plug 2. Antifreeze (1) Drain plug WARNING To avoid personal injury or death: When using antifreeze, put on some protection such as rubber gloves (antifreeze contains poison). If you swallow the antifreeze, seek immediate medical help. Do not make a person throw up unless told to do so by a poison control or a healthcare professional. Use standard first aid and CPR for signs of shock or cardiac arrest. Call your local poison control center or your local emergency number for further assistance. 132 M5091,M5111 Coolant capacity 10 L