Kubota — 10. Checking amount of refrigerant (gas)

SERVICE AS REQUIRED PERIODIC SERVICE In the event of a leakage, wear safety goggles. Escaping refrigerant can cause severe injuries to eyes. In contact with a flame, R134a refrigerant produces a toxic gas. Do not disconnect any part of the refrigeration circuit of the air conditioning system. Consult your local KUBOTA Dealer for assistance and service. A shortage of refrigerant impairs the air conditioner performance. Check the following points. If it is indicated that the amount of refrigerant is extremely low, ask your dealer to inspect and refill. Checking procedure 1. Run the air conditioner in the following conditions.

Engine speed - About 1500 rpm Temperature control dial - Maximum cooling position Fan switch - Highest blow Air conditioner switch - 2. Look into the sight glass to see if and how the refrigerant is flowing through its circuit. (1) Sight glass Proper Little or no air bubbles in the refrigerant flow. Lots of air bubbles in the refrigerant flow (air bub- bles or foam passing continuously). Low Overfull or no re- frigerant: Colorless and transpar- ent. IMPORTANT : Charge only with R134a, not R12 refrigerant. M5091,M5111 139