hitachi — Hitachi ZX14-3/ZX16-3/ZX18-3/ZX27-3 Hydraulic Excavator Operator's Manual

OPERATING MACHINE Emergency Boom Lowering Procedure d WARNING: Prevent personal injury. Confirm that no one is under the front attachment before starting the procedure below. If the engine stalls and cannot be restarted, lower the boom to lower the bucket to the ground referring to the emergency boom lowering procedure stated below. 1. Remove (open) the cover above the hydraulic oil tank. Loosen filler cap (1) on the hydraulic oil tank to release air pressure from the hydraulic oil tank. 1 d WARNING: Be sure to work only after oil temperature 1 ZX14-3, 16-3, 18-3 M1NC-00-010 is low or before operation. Failure to do so may allow high temperature oil to spray, possibly causing severe burns.

2. Remove cover (2) and cover (3). ZX27-3 M1NC-05-011 ZX27-3 M1NC-05-012 2 ZX14-3, 16-3, 18-3 2 3 M1NC-05-006 5-25