hitachi — Hitachi ZX14-3/ZX16-3/ZX18-3/ZX27-3 Hydraulic Excavator Operator's Manual

MAINTENANCE Electrolyte Level Check Check the electrolyte level at least once a month. 1. Park the machine on level ground and stop the engine. 2. Check the electrolyte level. 2.1 When checking the level from the battery side: Clean around level check lines with a wet towel. Do not use a dry towel. Static electricity may be developed, causing the battery gas to explode. Check if the electrolyte level is between U.L (Upper level) and L.L (Lower level). In case the electrolyte level is lower than the middle level between the U.L and L.L, immediately refill distilled water or commercial battery fluid. Be sure to refill with distilled water before recharging (operating the machine).

After refilling, securely tighten the filler plug. U.L (Upper Level) L.L (Lower Level) M146-07-109 Filler Port Sleeve 2.2 When it is impossible to check the level from the U.L (Upper Level) L.L (Lower Level) battery side or no level check mark is indicated on the side: Separator Top M146-07-110 After removing the filler plug from the top of the battery, check the electrolyte level by viewing through the filler port. It is difficult to judge the accurate electrolyte level in this case. Check if the electrolyte surface touches the bottom end of the sleeve or not according to the right illustrations.

When the electrolyte surface is lower than the bottom end of the sleeve, refill with distilled water or commercial battery fluid up to the bottom end of the sleeve. After refilling, securely tighten the filler plug. Proper Since the electrolyte surface touches the bottom end of the sleeve, the electrolyte surface is raised due to surface tension so that the electrode ends are seen curved. M146-07-111 Lower When the electrolyte surface is lower than the bottom end of the sleeve, the electrode ends are seen straight. M146-07-112 2.3 When an indicator is available to check the level, follow its check result. 3.

Always keep the vicinity around the battery terminals clean to prevent battery discharge. Check battery terminals for looseness and rust. Coat terminals with grease or petroleum jelly to the terminals to prevent corrosion. M409-07-072 7-60