Detroit Diesel — Installation of DIN Common Rail Fuel Pressure Sensor

5. Strip the end of each wire from the harness and splice it to the appropriate harness adaptor wire listed in Table 2. Solder or crimp the splice. 7. Cover all 3 spliced wires with an overall heat shrink tube. This tube should overlap the braided covering on the adapter end and on the harness end. Solder splicing is preferred, but crimp splices are acceptable. NOTE: NOTE: Do not cover the entire adapter with heat shrink tube. The heat shrink should end 3-1/2 inches from the back of the connector to allow the sensor to vent through the braided covering. See Figure 1. 6. Cover each wire splice with heat shrink tubing, preferably the self-adhesive type, so that no bare wire is exposed. 8.

Connect the harness adaptor to the new sensor, reconnect battery power, start the engine, and check for proper sensor operation. 1. Heat Shrink Tubing Figure 1. Location of Heat Shrink Tubing 13400 Outer Drive, West, Detroit, Michigan 48239-4001 Telephone: 313-592-5000 www.detroitdiesel.com 18SP503 Page 2 of 2 Detroit Diesel ® , DDC ® , Series 50 ® , Series 60 ® , and the spinning arrows design are registered trademarks of Detroit Diesel Corporation. Series 2000™ and Series 4000™ are trademarks of Detroit Diesel Corporation. 18SP503 0008 © Copyright 2000 Detroit Diesel Corporation. All rights reserved. Printed in U.S.A.