HIGH PRESSURE FUEL LINE HIGH-PRESSURE LINE TO A-BANK RAIL. HIGH-PRESSURE LINE TO B-BANK RAIL Fig. 57 High-pressure Fuel Line System Fig.58 High-pressure line connector Fig. 59 High-pressure line from rails to injectors All the high-pressure fuel lines are designed to carry the fluctuating high- pressures of this system by utilizing a unique double walled construction. This double walled construction consists of a stainless steel inner wall with a copper protective outer wall forming an air vent passage between them.
Care should be taken at anytime the high-pressure fuel line is removed from an injector as breaking the torque on the outer retaining nuts will also loosen the inner retaining nuts and could cause improper seating if not properly retorqued before re-installation. Care must be taken to protect these sealing surfaces at any time the high-pressure lines or flow-Limiter valves are removed as damage to these sealing surfaces can result in a high-pressure fuel leaks. Page 43 FUEL LEAK DETECTION LINE PORT