Fig. 78 There are flow-limiter valves for each injector to prevent over fueling of the cylinder should something happen to an injector. The flow-limiter valves are located on each bank between the injector high-pressure fuel lines and the high- pressure fuel rail. These valves sense fuel flow and will shut off the flow of fuel to the injector if the flow rate exceeds the spring tension of the flow-limiter valve. This is normally 1.5 times the normal injector fueling rate. Fig.
79 FLOW-LIMITER VALVE DISASSEMBLED The flow limiter valves consist of spring and a valve, which floats in the fuel flow until the flow exceeds that of the spring, thereby causing the valve to close on the seat of the body. The fuel inlet from the high-pressure rail is tapered to accept the cone shaped nozzle of the flow-limiter valve. The outlet of the flow-limiter valve also is cone shaped to accept the injector high-pressure fuel line. The conditions of this cone shaped sealing areas are very important in the prevention of fuel leaks.
Anytime the injector high-pressure lines are removed; care should be taken to protect all the sealing surfaces of the flow-limiter valve, high-pressure rail and the injector high-pressure fuel line. Page 53 FLOW- LIMITER VALVE FLOW- LIMITER VALVE No Fuel to Injector Fuel to Injector Fuel Volume Limit Spring Valve High Pressure Fuel Rail Valve Open Valve Closed