CHECKING THE SWITCH CHECKING THE SWITCH CHECKING THE SWITCH Use a pocket tester to check the terminals for continuity. If the continuity is faulty at any point, replace the switch. NOTE: Set the pocket tester to “0” before starting the test. The pocket tester should be set to the Ω Ч range when testing the switch for continuity. Turn the switch on and off a few times when checking it. CHECKING A SWITCH SHOWN IN THE MANUAL The terminal connections for switches (main switch, handlebar switch, engine stop switch, light switch, etc.) are shown in a chart similar to the one on the left. This chart shows the switch positions in the column and the switch lead colors in the top row.
For each switch position, “ ” indicates the terminals with continuity. The example chart shows that: 1 There is continuity between the “Red, Brown/ Blue, and Brown” leads when the switch is set to 9 - 2 ELEC – + Pocket tester: P/N. YU-03112, 90890-03112