Yamaha Grizzly 660 — Yamaha Grizzly 660 User Manual

MAINTENANCE SPECIFICATIONS 2 - 10 SPEC Item Standard Limit Radiator cap opening pressure Radiator capacity Coolant reservoir Capacity From low to full level 93.3 ~ 122.7 kPa (0.933 ~ 1.227 kg/cm2, 13.53 ~ 17.79 psi) 0.78 L (0.69 Imp qt, 0.82 US qt) 0.3 L (0.26 Imp qt, 0.32 US qt) 0.165 L (0.15 Imp qt, 0.17 US qt) ---- ---- ---- ---- Water pump: Type Reduction ratio Single suction centrifugal pump 32/31 (1.032) ---- Thermostat: Valve opening temperature Valve full open temperature Valve lift-full open 50 ~ 54 °C (122.0 ~ 129.2 °F) 70 °C (158 °F) 8 mm (0.31 in) ---- ---- ---- Shaft drive:

Middle gear backlash Final gear backlash Differential gear backlash 0.1 ~ 0.3 mm (0.004 ~ 0.012 in) 0.1 ~ 0.2 mm (0.004 ~ 0.008 in) 0.05 ~ 0.25 mm (0.002 ~ 0.010 in) ---- ---- ---- Lubrication chart: Delivery pipe 3 Delivery pipe 2 Delivery pipe 1 Oil filter Cylinder head Crankshaft and Drive axle and perimeter perimeter Relief valve Oil pump Oil pan Oil strainer