Komatsu — SWITCHES

. OPERATION DETAILED CONTROLS AND GAUGES Emergency Pump Drive Switch NOTICE (a) EMERGENCY: When abnormal (move switch up) (b) NORMAL: When normal (move switch down) Swing Parking Brake Release Switch (a) FREE: When abnormal (move switch up) (b) NORMAL: When normal (move switch down) 3 - 39 Emergency pump drive switch is provided to make it possible to perform work for a short t ime when there is a failure in the pump control system. It is necessary t o repair the abnormal location as soon as possib This switch (10) is used to ma ke it possible to carry out operations temporarilyif any problem sho uld occur in the pump control system (when the display shows "E0 2").

If the display shows "E02", m ove the switch up to make it possible to carry out work. NOTICE This switch makes it possible to perform swing operations for a short tim e even when t here is a problem in the swing parking brake electric system. DO NOT u se this switch except in emergencies. Repair the proble m as soon as possi ble. This switch (11) is used to ma ke it possible to carry out operations temporarily if any problem sh ould occur in the swing parking brake system (when the upper stru does not show "E03"). cture does not swing but the display If the display does not sho w "E03", move the switch up to FREE position (a) to make it pos sible to carry out work.

When the switch is moved to FREE position (a), the swing lock monitor flashes. Step Light Switch unting the machine at night. Use switch (12) when dismo When the switch is pressed , the step light will light up for approx. 60 seconds. Even if the starting switch key is at the OFF position, the step ox. 60 seconds when the switch is light will light up for appr pressed.