BODY (UPPERSTRUCTURE) / Control Valve 16. Install O-ring (31) to housing (32). Install housing (30) to housing (32) with bolts (44) (4 used). : 145 to 159 N m (14.8 to 16.2 kgf m, 107 to 117 lbf ft) 17. Install relief valve (28) to housing (30). : 12 mm : 103 to 113 N m (10.5 to 11.5 kgf m, 76 to 83 lbf ft) 18. Install relief valve (33) to housing (32). : 38 mm : 78 to 88 N m (8 to 9 kgf m, 57.5 to 65 lbf ft) 19. Install O-ring (8) to the groove on the flange (7) mounting position in housing (32). Install poppet (10), spring (9) and flange (7) to housing (32). Install flange (7) to housing (32) with socket bolts (6) (2 used). : 38 mm : 5 mm :
58 to 64 N m (6 to 6.5 kgf m, 43 to 47 lbf ft) 20. Install plug (39) to housing (32). : 5 mm : 80 to 86 N m (8.2 to 8.8 kgf m, 58 to 63 lbf ft) W2-7-31