hitachi — T03-06-01to16.pdf

SYSTEM / Electrical System Regulator Operation When generating voltage increases more than the set-voltage of Zener diode ZD, current flows to base B of transistor T2 and collector C is connected to emitter E. Current which was routed to base B of transistor T1 disappears due to transistor T2 operation so that transistor T1 is turned OFF. No current flows through filed coil FC and generating voltage at stator coil SC decreases. When generating voltage decreases lower than the set-voltage of Zener diode ZD, transistor T2 is turned OFF and transistor T1 is turned ON again. Current flows through field coil FC and generating voltage at stator coil SC increases.

The above operation is repeated so that the alternator generating voltage is kept constant. Battery Relay RF R 3 R 4 R 5 R 6 ZD Battery SC B R 2 A E FC B C T 2 R 1 C E (F) D 1 T 1 E (E) T157-04-02-009 T2-5-15