SYSTEM / Electrical System SECURITY LOCK CIRCUIT 1. When the external alarm signal or password input error signal from ICF is input to the monitor unit, terminal #A4 is connected to the ground inside the monitor unit. 2. Therefore, the security relay and starter cut relay are excited. 3. When the security relay is excited, the ground circuit in pilot shut-off solenoid valve is blocked and the pilot shut-off solenoid valve is turned OFF. 4. Therefore, pressure oil which flows to the pilot valve from the pilot pump is blocked by the pilot shut-off solenoid valve. 5.
When the starter cut relay is excited, the circuit between terminal ST in the key switch and terminal S in starter relay 2 is blocked. 6. Therefore, when the key switch is turned to the START position, the engine does not start. T2-5-20