COMPONENT OPERATION / Pump Device Link Mechanism The movement of pilot piston (22) is transmitted through pin (21) to lever 1 (18). Lever 1 (18) is turned about pin (19) which is fixed to the axial plug. The movement of pilot piston (11) is transmitted through pin (12) to lever 2 (4). Lever 2 (4) is turned about pin (5) which is fixed to the housing. Pin (7) is attached to feedback lever (13). Both ends of pin (7) are inserted into holes (23, 8) on lever 1 (18) and lever 2 (4). Therefore, when lever 1 (18) or lever 2 (4) turns, pin (7) contacts the hole of the turned lever. Feedback lever (13) turns about pin (14) attached to servo piston (15).

In addition, when servo piston (15) moves, feedback lever (13) is moved through pin (14). At this time, as neither lever 1 (18) nor lever 2 (4) move, feedback lever (13) turns about pin (7). Axial Plug T1J1-03-01-007 2 - Spool 7 - Pin 13 - Feedback Lever 19 - Pin 4 - Lever 2 8 - Hole 14 - Pin 21 - Pin 5 - Pin 11 - Compensating Rod 15 - Servo Piston 22 - Pilot Piston 6 - Pin 12 - Pin 18 - Lever 1 23 - Hole T3-1-14 Housing 5 NOTE : Displacement A 12 4 : Displacement A 8 11 13 6 7 18 23 19 2 21 14 22 15 12 4 8 18 23