hitachi — BUCKET FLOW RATE CONTROL VALVE CONTROL SPOOL, FLOW COMBINER VALVE CONTROL SPOOL, SWING PARKING BRAKE RELEASE SPOOL, ARM 1 FLOW RATE CONTROL VALVE CONTROL SPOOL

COMPONENT OPERATION / Others (Upperstructure) 5. When piston B moves to the left, grease from the grease pump acts on the right side of piston C through passage K. 6. Therefore, piston C moves to the left. Grease at the left side of piston C flows to port 9 through passage L and piston B. 7. By repeating steps 3 to 6, grease is supplied to ports 11, 9, 7, 5 and 3 in this order. From Grease Pump Passage L Passage K Port 11 A Port 12 Port 9 B Port 10 Port 7 C Port 8 Port 5 D Port 6 Port 3 E Port 4 Port 1 F Port 2 T1J1-03-07-008 From Grease Pump 8. When piston F moves to the left, grease from the grease pump acts on the left side of piston A through passage H. 9.

Therefore, piston A moves to the right. Grease at the right side of piston A flows to port 1 through passage G and piston F. Port 11 A Port 12 Port 9 B Port 10 Port 7 C Port 8 Port 5 D Port 6 Port 3 E Port 4 Port 1 F Port 2 T1J1-03-07-009 Passage G Passage H From Grease Pump 10. When piston A moves to the right, grease from the grease pump acts on the left side of piston B through passage J. 11. Therefore, piston B moves to the right. Grease at the right side of piston B flows to port 12 through passage I and piston A. 12. By repeating steps 10, 11, grease is supplied to ports 12, 10, 8, 6 and 4 in this order.

Passage J Passage I Port 11 A Port 12 Port 9 B Port 10 Port 7 C Port 8 Port 5 D Port 6 Port 3 E Port 4 Port 1 F Port 2 T1J1-03-07-010 T3-7-11