Scania — Checking and adjusting the valve clearance

Miscellaneous Checking and adjusting the valve clearance Note: Checking and adjusting valve clearances should also be done one more time after the first 500 hours of operation. Then the normal interval will follow (every 2,000 hours). Valve clearances should be adjusted when the engine is cold, at least 30 minutes after running. WARNING! Block the starting device when working on the engine. If the engine starts unexpectedly, there is a serious risk of injury. Readings can be taken from the flywheel through openings in the flywheel housing either from above or below depending on access when fit- ting. “TDC up” or ”"TDC down" is found on the fly- wheel.

Both openings are fitted with a blanking piece on delivery. 310 343 Openings for taking readings on the flywheel hous- ing. OPM 100 en-GB 66 © Scania CV AB 2015, Sweden Intake valve clearance 0.45 mm (0.018 in) Exhaust valve clearance 0.70 mm (0.028 in)