STRUCTURE AND FUNCTION HYDRAULIC TANK HYDRAULIC TANK 1. Filter bypass valve Outline 2. Filter ! The oil from the hydraulic tank is sent from the 3. Breather pump through the priority valve and main control 4. Oil level gauge valve to each cylinder. In the return circuit, it is 5. Drain valve filtered by the oil filter, and returns to the tank. ! The oil filter filters the whole oil flow in the circuit. When the oil filter becomes clogged, the bypass valve is actuated to allow the oil to return directly to the tank and prevent damage to the filter. The bypass valve is also actuated when negative pressure is generated in the circuit. 10-85