Komatsu — TRANSMISSION CONTROL VALVE

MAINTENANCE STANDARD TRANSMISSION CONTROL VALVE LOWER VALVE Unit: mm 40-18 No.

Check item Criteria Remedy 1 Clearance between torque converter regulator valve and body Standard size Tolerance Standard clearance Clearance limit Replace Shaft Hole 19 -0.02 -0.03 +0.013 0 0.020 - 0.043 0.050 2 Clearance between F-R selector spool and body 19 -0.02 -0.03 +0.013 0 0.020 - 0.043 0.050 3 Clearance between H-L selector spool and body 19 -0.02 -0.03 +0.013 0 0.020 - 0.043 0.050 4 Clearance between range selector spool and body 19 -0.02 -0.03 +0.013 0 0.020 - 0.043 0.050 5 Torque converter regulator valve spring Standard size Repair limit Free length Installed length Installed load Free length Installed load 70.3 66.1 55.7 ± 2.7 N (23.46 ± 1.17 kg) 67.5 50 N (5.1 kg) 6 F-R selector spool spring 48.8 36 83.4 ± 4.2 N (8.5 ±0.43 kg) 46.8 75.5 N (7.7 kg) 7 H-L range selector spool return spring 48.0 36.7 69.8 ± 3.5 N (7.12 ± 0.036 kg) 46.1 62.8 N (6.4 kg)