Komatsu — QUICK RETURN VALVE

STRUCTURE AND FUNCTION TRANSMISSION CONTROL VALVE 4. Start of accumulator action, clutch completely engaged (clutch pressure at point D) ! Because of the differential pressure created by ! when accumulator piston (8) moves to the end of its modulation fill valve (1 1), a constant flow of oil stroke, the rise in the pressure at port d finishes, so passes through 1st orifice (10) and enters the specified pressure is maintained and the accumulator (8). As this oil flows in, the REVERSE clutch is completely engaged. accumulator piston gradually moves to the right in When the gear shift spool is operated, the action is the direction of the arrow, and spring (9) is the same as above.

compressed, so the accumulator pressure rises. As this accumulator pressure rises, it raises the clutch pressure. Except in 1st, oil flows into the accumulator from 1st orifice + 2nd (3rd) orifice, so the modulating time is shorter than for 1st. 10-37